Overview
BICC Cables is an Egyptian company previously owned by US-based General Cables. It manufactures a wide variety of wire and low voltage cable products for the electricity markets, including insulated power and control cables, building wire, instrumentation cable, halogen-free power and control cables, and overhead power cables.
The company is a great addition to the group because of its profitable track record and a capable management team boasting great technical knowhow. Considering the diverse infrastructure projects underway in Egypt, the company processes significant potential growth.
BICC Cables is certified with quality management system ISO 9001:2015, and health and safety management OHSAS 18001.
BICC Cables Products
Our BICC Cables company, currently launching a new line of business, is expanding its production to include medium and high voltage cables. This strategic expansion aims to cover the segment cabling, offering a more comprehensive selection of cables to meet diverse market needs and to provide a turn-key solution in this segment. In addition to that, we aim to expand our MENA and international sales market. The production of our cables, including the existing low voltage, wires and instrumentation cables takes place in our factory located in Egypt. Complying with British Standards (BS) and International Specification IEC requirements, our products are renowned for their quality and reliability. As a result, multinational companies rely on us to deliver cables tailored to their specific needs.
At BICC Cables, our plant is managed by proficient teams, both in management and technical expertise, ensuring the production of cables that meet the highest international standards and diligently work towards customer satisfaction and fostering long-term partnerships.
Whether you require low, medium, or high voltage cables, explore your market needs and discover how BICC can assist you.
The factory is capable of manufacturing and supplying power cables in the following ranges:
Single Core – Copper Cables:
Applications:
For indoor fixed installations in dry locations, laid in conduits, as well as in steel support brackets.
Maximum operating temperature: 70°
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor fixed installations in dry locations, where flexibility is required. For electrical panels connection or for electrical apparatus. they can be laid in groups around steel sheet.
Maximum operating temperature: 70°C
Construction:
Conductor: Copper, flexible class 5
Insulation: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For outdoor and indoor installations in damp and wet locations, they are normally used for power distribution in urban networks. industrial plants. As well as in thermopower and hydropower stations
Maximum operating temperature: 70°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For outdoor and indoor installations in damp and wet locations, they are normally used for power distribution in urban networks. industrial plants. As well as in thermopower and hydropower stations.
Maximum operating temperature : 90°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Cross-Linked polyethylene [XLPE]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Single Core – Aluminium Cables:
Applications:
For indoor fixed install actions in dry locations, laid in conduits, as well as in steel support brackets. Maximum operating temperature :70°C
Construction:
Conductor: Aluminum, semi-rigid class 2
Insulation: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks. industrial plants. as well as in thermos power and hydropower stations.
Maximum operating temperature :70°C
Construction:
Conductor: Aluminum, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
for indoor and outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks. industrial plants. as well as in thermopower and hydropower stations.
Maximum operating temperature :90°C
Construction:
Conductor: Aluminum, semi-rigid class 2
INSULATION: Cross-linked polyethylene [XLPE]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Multi Core – Copper Cables:
Applications:
For outdoor and indoor installations in damp and wet locations. Maximum operating temperature: 70°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations, where mechanical damage is expected to occur.
Maximum operating temperature :70°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Armour:Double Steel Tape
Sheath:Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations, where mechanical damage is expected to occur.
Maximum operating temperature :70°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Armour: Steel wires
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
Simi-rigid for use in low voltage power distribution in fixed indoor and outdoor installations.
Maximum operating temperature :90°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Cross-Linked polyethylene [XLPE]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations, where mechanical damage is expected to occur.
Maximum operating temperature :90°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Cross-linked polyethylene [XLPE]
Armour: Double Steel Tape
Sheath:Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations, where mechanical damage is expected to occur.
Maximum operating temperature :90°C
Construction:
Conductor: Copper, semi-rigid class 2
Insulation: Cross-linked polyethylene [XLPE]
Armour: Steel Wire
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Multi Core – Aluminium Cables:
Applications:
For indoor and outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants, as well as in thermos power and hydropower stations.
Maximum operating temperature :70°C
Construction:
Conductor: Aluminium, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants, as well as in thermos power and hydropower stations.
Maximum operating temperature :70°C
Construction:
Conductor: Aluminum, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Armour: Double Steel Tape
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations, where mechanical damage is expected to occur.
Maximum operating temperature :70°C
Construction:
Conductor: Aluminium, semi-rigid class 2
Insulation: Polyvinyl Chloride [PVC]
Armour: Steel Wire
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations. Maximum operating temperature :90°C
Construction:
Conductor: Aluminium, semi-rigid class 2
Insulation: Cross-Linked polyethylene [XLPE]
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations, where mechanical damage is expected to occur.
Maximum operating temperature :90°C
Construction:
Conductor: Aluminium, semi-rigid class 2
Insulation: Cross-linked polyethylene [XLPE]
Armour: Double Steel Tape
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
Applications:
For indoor and outdoor installations in damp and wet locations, where mechanical damage is expected to occur.
Maximum operating temperature :90°C
Construction:
Conductor: Aluminium, semi-rigid class 2
Insulation: Cross-linked polyethylene [XLPE]
Armour: Steel Wire
Sheath: Polyvinyl Chloride [PVC]
PRODUCT INQUIRY:
All Aluminum Conductors (AAC)
All aluminum conductor is the most favored type for use in the construction of short span distribution schemes and are in common use on lines for voltage up to 60 kV.
Another frequent application for all aluminum conductor is in flexible bus bar connection.
Although aluminum to copper connections can be made, it is better to use aluminum conductors for service connections, as various forms of covered cable available for this purpose.
The data sheets show the most common sizes of conductor but other sizes, to any recognized standards or customer, can also be supplied.
AAC insulated with XLPE or PVC can also be supplied as per customers’ requirements.
PRODUCT INQUIRY:
Aluminum Conductors Steel Reinforced (ACSR)
The mixed construction of ACSR makes it a very flexible medium from design point of view. By varying the relative proportion of aluminum and steel, the ideal conductor for any particular application can be produced. Generally, ACSR Consists of a galvanized steel core of 1 wire, 7 wires or 19 wires surrounding by concentric layers of aluminum wire. When a conductor with a high a high current carrying capacity and comparatively low strength required, special construction is available with a high aluminum content.
Protection against corrosion
A coating of non- oxidizing grease is normally applied to steel cores of all conductors, in addition to the Protection offered by the galvanizing of the steel wires. One or more layers of the aluminum wires can, if required, be supplied partially or fully greased.
BICC Cables ensures complete freedom from contamination by other metals during the entire manufacture of ACSR conductors.
PRODUCT INQUIRY:
PRODUCT INQUIRY:
Applications:
Overhead transmission system
Overhead traction system
Transformer earthing (occasionally)
PRODUCT INQUIRY:
Instrumentation Cables
Multi Pair/ Triple & Multi Core Instrument Cables:
These cables are designed to connect electrical instrument circuits and provide communication services working as signal carrier used in and around process plants (e.g. petrochemical industry etc.).
Application:
Multi pair/triple & multi core instrument cables are used as signal carrier for connecting electrical instrument circuits.
Construction:
Conductor: Stranded Copper class 2
Insulation: Polyvinyl Chloride (PVC)
Alternative: Cross Linked Polyethylene (XLPE)
Shielding: Overall Shielding
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
Multi pair/triple instrument cables are used as signal carrier for connecting electrical instrument circuits.
Construction:
Conductor: Stranded Copper class 2
Insulation: Polyvinyl Chloride (PVC)
Alternative: Cross Linked Polyethylene (XLPE)
Shielding: Individual & Overall Shielding
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
Multi pair/triple & multi core instrument cables are used as signal carrier for connecting electrical
instrument circuits.
Construction:
Conductor: Stranded Copper class 2
Insulation: Polyvinyl Chloride (PVC)
Alternative: Cross Linked Polyethylene (XLPE )
Shielding: Overall Shielding
Armour: Galvanized Round Steel Wire (GSWA)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
Multi pair/triple instrument cables are used as signal carrier for connecting electrical instrument circuits.
Construction:
Conductor: Stranded Copper class 2
Insulation: Polyvinyl Chloride (PVC)
Alternative: Cross Linked Polyethylene (XLPE)
Shielding: Individual & Overall Shielding
Armour: Galvanized Round Steel Wire (GSWA)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Control Cables
Application:
Control cables are used as interconnecting cables for control devices for outdoor and indoor installation.
Construction:
Conductor: Stranded Copper class 2
Insulation: Polyvinyl Chloride (PVC)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
Control cables are used as interconnecting cables for control devices for outdoor and indoor installations.
Construction:
Conductor: Stranded Copper class 2
Insulation: Cross Linked Polyethylene (XLPE)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
Control cables are used as interconnecting cables for control devices and armoured cables in environment where mechanical damage is expected to occur.
Construction:
Conductor: Stranded Copper class 2
Insulation: Polyvinyl Chloride (PVC)
Armour: Galvanized Round Steel Wire (GSWA)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
Control cables are used as interconnecting cables for control devices and armored cables in environment where mechanical damage is expected to occur.
Construction:
Conductor: Stranded Copper class 2
Insulation: Cross Linked Polyethylene (XLPE)
Armour: Galvanized Round Steel Wire (GSWA)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
These cables are used for interconnecting control devices and designed to be complete with copper tape screen applied helically after bedding.
Construction:
Conductor: Stranded Copper class 2
Insulation: Polyvinyl Chloride (PVC)
Screen: Copper Tape Screen (CTS)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Application:
These cables are used for interconnecting of control devices and designed to be complete with copper tape screen applied helically.
Construction:
Conductor: Stranded Copper class 2
Insulation: Cross Linked Polyethylene (XLPE)
Screen: Copper Tape Screen (CTS)
Sheath: Polyvinyl Chloride (PVC)
PRODUCT INQUIRY:
Fire Resistant Cables
Application:
These cables are used for interconnecting control devices mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.
Construction:
Conductor: Stranded Copper class 2
Fire resistance material: MICA Glass Tape
Insulation: Cross Linked Polyethylene (XLPE)
Sheath: Low Smoke Zero Halogen (LSOH)
PRODUCT INQUIRY:
Application:
These cables are used for interconnecting control devices, mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.
Construction:
Conductor: Stranded Copper class 2
Fire Resistance Material: MICA Glass Tape
Insulation: Cross Linked Polyethylene (XLPE)
Armour: Galvanized Round Steel Wire (GSWA)
Sheath: Low Smoke Zero Halogen (LSOH)
PRODUCT INQUIRY:
Application:
These cables are used as signal carrier for connecting electrical instrument circuits, mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.
Construction:
Conductor: Stranded Copper class 2
Fire Resistance Material: MICA Glass Tape
Insulation:Cross Linked Polyethylene (XLPE)
Shielding: Overall Shielding
Sheath: Low Smoke Zero Halogen (LSOH)
PRODUCT INQUIRY:
Application:
These cables are used as signal carrier for connecting electrical instrument circuits, mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.
Construction:
Conductor: Stranded Copper class 2
Fire resistance material: MICA Glass Tape
Insulation: Cross Linked Polyethylene (XLPE)
Shielding: Individual & Overall Shielding
Sheath: Low Smoke Zero Halogen (LSOH)
PRODUCT INQUIRY:
Fire Alarm Cables
Application:
Used as a part of the fir fighting system for the connection with security systems like smoke detectors, emergency lightings, exit signboards and fire command center.
These cables are used where the fire safety is utmost important where residential area, schools , hospitals, ….etc.
Design:
Designed and tested as per BS 50288-7.
Voltage rating 500V.
Construction:
Conductor: Annealed Copper as per IEC 60228
Insulation: PVC rated 105°C
Screen: Aluminum foil+ Polyester tape in contact with drain wire Or Without Screen (upon request)
Sheath: PVC rated 105°C
Further Options:
Cable can be used to maintain circuit integrity too where mica glass tape and insulation and sheath of Low Smoke Zero Halogen (LSOH) shall be used.
PRODUCT INQUIRY:
Our Certifiers
Our Key Clients
Find us on
Get in touch
Phone number: +20 1270600060
…………………+20 35390251 (2-3-4-5)
Fax: +20 35390256
Email: info@bicccables.com